Wind loads for designing ground-mounted solar-panel arrays
Journal Publication ResearchOnline@JCUAbstract
Net wind pressures acting across solar panels were obtained by testing 1/20 scale models in a range of typical array configurations in the wind tunnel. This paper presents data for a typical panel array configuration inclined at α = 20°. Large net negative (upward) pressures were measured on the panels at the leading edges for wind blowing towards the bottom surface of the sloping panels. Shielding from upwind arrays was negligible. Large net positive (downward) pressures were measured on the panels at the bottom leading edge for wind blowing towards the top surface of the sloping panels. Aerodynamic shape factors Cshp on the panels and arrays are given in a form that has been proposed in the revision of the Australian/New Zealand wind loading standard AS/NZS 1170.2.
Journal
Australian Journal of Structural Engineering
Publication Name
N/A
Volume
20
ISBN/ISSN
1328-7982
Edition
N/A
Issue
3
Pages Count
15
Location
N/A
Publisher
Institution of Engineers
Publisher Url
N/A
Publisher Location
N/A
Publish Date
N/A
Url
N/A
Date
N/A
EISSN
N/A
DOI
10.1080/13287982.2019.1623001